Stopdiagnosticsession.vi, Stopdiagnosticsession.vi -68 – National Instruments CAN 372139B-01 User Manual

Page 94

Advertising
background image

Chapter 5

Automotive Diagnostic Command Set API for LabVIEW

Automotive Diagnostic Command Set User Manual

5-68

ni.com

StopDiagnosticSession.vi

Purpose

Executes the StopDiagnosticSession service. Returns the ECU to normal mode.

Format

Input

diag ref in specifies the diagnostic session handle, obtained from

Open

Diagnostic.vi

and wired through subsequent diagnostic VIs. Normally, it is

not necessary to manually manipulate the elements of this cluster.

error in is a cluster that describes error conditions occurring before the VI
executes. If an error has already occurred, the VI returns the value of the
error in cluster to error out.

status is TRUE if an error occurred. This VI is not executed when
status is TRUE.

code is the error code number identifying an error. A value of 0
means success. A negative value means error: the VI did not
execute the intended operation. A positive value means warning:
the VI executed intended operation, but an informational warning
is returned. For a description of the code, wire the error cluster to
a LabVIEW error-handling VI, such as the Simple Error
Handler
.

source identifies the VI where the error occurred.

Output

diag ref out is a copy of diag ref in. You can wire it to subsequent
diagnostic VIs.

success? indicates successful receipt of a positive response message for
this diagnostic service.