Figure 2-3. wiring power to the ni 1450, Connecting to a separate main supply – National Instruments NI 1450 Series User Manual

Page 24

Advertising
background image

Chapter 2

Setup and Configuration

NI 1450 Series Compact Vision System User Manual

2-10

ni.com

The NI 1450 ships with a factory-installed startup program that, when the
NI 1450 is connected to a camera and powered on, acquires images and
displays them on the monitor. If these images from the camera display on
the monitor, continue to the

Connecting the NI 1450 to the Development

Computer

section. If the images from the camera are not displayed on the

monitor, refer to Appendix A,

Troubleshooting

.

Figure 2-3. Wiring Power to the NI 1450

Connecting to a Separate Main Supply

If you are using a power supply other than the NI desktop power supply,
use this section to connect power to the NI 1450.

Caution

Do not connect the NI 1450 main power to a source other than 24 VDC ±10%.

Do not connect the NI 1450 isolated power to a source less than 5 VDC or greater than
30 VDC. Doing so could damage the NI 1450.

1

4-Position Power Connector

2

NI Desktop Power Supply

3

Power Supply Cord (to Outlet)

1

3

To Outlet

2

Advertising