Chapter 4

Digital I/O Functionality

NI 1450 Series Compact Vision System User Manual

4-12

ni.com

Figure 4-5. Example of Connecting an Isolated Input to a Sourcing Output Device

Wiring an Isolated Output to an External Load

The digital output circuit sources current to external loads, as shown in
the example in Figure 4-6. The maximum output current of this circuit
is 100 mA.

Figure 4-6. Example of Connecting an Isolated Output to an External Load

Vcc

Sourcing

Output
Device

Viso

Current

Limiter

Ciso

NI 1450

Input

Digital Output

Viso

Ciso

Vcc

NI 1450

Load