Figure 4-8. example connections, Typical system setup, Typical system setup -14 – National Instruments NI 1450 Series User Manual

Page 59

Advertising
background image

Chapter 4

Digital I/O Functionality

NI 1450 Series Compact Vision System User Manual

4-14

ni.com

Figure 4-8. Example Connections

When connecting to TTL inputs on the NI 1450 device, match the output
impedance of the transmitting device to the characteristic impedance of the
cable. For example, if the cable characteristic impedance is 118

Ω, make

R

s

equal to 118

Ω, as shown in Figure 4-8.

Typical System Setup

Digital I/O configuration varies depending on the number of cameras your
system setup requires. You can access the digital I/O through the 44-pin
DSUB connector or through the 3 SMB connectors.

The digital I/O capabilities of the SMB connectors on the NI 1450 are ideal
for typical single-camera applications. The SMB connectors are labeled
TRIG 0, TRIG 1, and TRIG 2.

TTL OUT(0)

Receiving

Equipment

TTL IN(0)

118

44-Pin

DSUB

3
2

16
17

62 k

Transmitting

Equipment

R

S

TRIG 1

75

TRIG 1

SMB

RG-179

Coaxial Cable

+5 V

NI 1450

Receiving

Equipment

Advertising