Cos-pvid, Configure, Diffserv – NETGEAR 700 Series Managed Switch for Software v2.1 User Manual

Page 102: Configure -12, Diffserv -12

Advertising
background image

700 Series Managed Switch User’s Guide for Software v2.1

6-12

Command Line Interface

SM-10004-02

<VLAN index #>

= The VLAN ID. Adding the VLAN ID to the show vlan command displays

the port that belongs to that particular VLAN. For example, show vlan 1 displays the ports that
belong to VLAN 1.

An example of the display output is shown below:.
Untagged port members: 4,5,7,11-15,19-23
Tagged port members: none

COS-PVID

The

show vlan cos-pvid

displays the PVIDs and the CoS settings of each port.

Syntax

FSM726# show vlan cos-pvid

An example of the display output is shown below:

Port PVID Priority
------------------------
1:1 1 Normal
1:2 1 Normal
1:3 1 Normal
1:4 1 Normal
1:5 1 Normal

Configure

Entering the command

configure

at the root prompt takes you into configuration mode. When

you’re in configuration mode, the prompt changes to

FSM726(config)#

It is in this mode where the vast majority of configuration is performed. To exit the configuration
mode and return to root prompt, use the exit command.

DiffServ

DiffServ divides traffic into one of 64 classes using the packet’s DSCP value. This allows for
greater differentiation of traffic priority than port-based traffic prioritization.

Syntax

Advertising