NetComm IG6000 User Manual

Page 14

Advertising
background image

Industrial Modem User Guide 

YML391­3A 

14 

General Commands 

+++ 

Escape Sequence 

Displays help.  May be followed by the command(s) or a keyword for which 

help is needed 

A/ 

Repeat Command 

B0 

Auto­Connect 

B1 

Auto­Connect 

B2 

Auto­Connect 

B3 

V.21 ­ 300 bps 

B4 

Bell 103 ­ 300 bps 

B5 

V.23 ­ 1200/75 bps 

B6 

V.22 ­ 1200 bps 

B7 

Bell 212A ­ 1200 bps 

B8 

V.22bis ­ 2400 bps 

B9 

Auto­Connect 

B10 

V.32 ­ 4800 bps 

B11 

V.32bis ­ 7200 bps 

B12 

V.32 (Non­TCM) ­ 9600 bps 

B13 

V.32 ­ 9600 bps 

B14 

V.32bis ­ 12000 bps 

B15 

V.32bis ­ 14400 bps 

B16 

V.34/V.Fast Class ­ 14400 bps 

B17 

V.34/V.Fast Class ­ 16800 bps 

B18 

V.34/V.Fast Class ­ 19200 bps 

B19 

V.34/V.Fast Class ­ 21600 bps 

B20 

V.34/V.Fast Class ­ 24000 bps 

B21 

V.34/V.Fast Class ­ 26400 bps 

B22 

V.34/V.Fast Class ­ 28800 bps 

B23 

V.34 31200 bps 

B24 

V.34 33600 bps 

E0 

Local command state echo off 

E1 

Local command state echo on 

H0 

Go on­hook 

H1 

Go off­hook 

I0 

Numeric firmware identity 

I1 

Checksum of firmware ­ return checksum 

I2 

Checksum of firmware ­ return OK/ERROR 

I3 

Modem Model 

I4 

Firmware Version and date 

I5 

Manufacturer ID 

I9 

Verbal firmware identity 

I10 

Display modem statistics 

L0 

Lowest volume level 

L1 

Low volume level 

L2 

Medium volume level 

L3 

Highest volume level 

M0 

Speaker is always off 

M1 

Speaker on when connecting, off when connected 

M2 

Speaker always on 

M3 

Speaker off when dialling or after connection established

Advertising