Industrial Modem User Guide 

YML391­3A 

15 

M4 

Speaker on during dial, answer, retrain or rate change 

O1 

Enter On­line state and force communication retrain (V.22bis and V.32bis only) 

O2 

Retrain, donÕt go on­line (V.22bis & V.32bis) 

O3 

Change line speed to 4800 bps (V.32 & V.32bis) 

O4 

Change line speed to 7200 bps (V.32 & V.32bis) 

O5 

Change line speed to 9600 bps (V.32 & V.32bis) 

O6 

Change line speed to 12000 bps (V.32 & V.32bis) 

O7 

Change line speed to 14400 bps (V.32 & V.32bis) 

Pulse dialling 

Q0 

Modem returns response codes 

Q1 

Modem does not return response codes 

Q2 

Modem does not return RINGING or response codes when answering 

R9 

9600 bps (locked terminal speed ­ no autobaud) 

R14 

14,400 bps (locked terminal speed ­ no autobaud) 

R19 

19,200 bps (locked terminal speed ­ no autobaud) 

R28 

28,800 bps (locked terminal speed ­ no autobaud) 

R38 

38,400 bps (locked terminal speed ­ no autobaud) 

R57 

57,600 bps (locked terminal speed ­ no autobaud) 

R115 

115,200 bps (locked terminal speed ­ no autobaud) 

R230 

230,400 bps (locked terminal speed ­ no autobaud) 

Sn? 

Display value in S Register ÔnÕ 

Sn=x 

Place ÔxÕ in S Register ÔnÕ 

Tone dialling 

V0 

Numeric response codes 

V1 

Verbal response codes 

W0 

CONNECT message reports the terminal speed 

W1 

CONNECT message reports the terminal speed 

W2 

CONNECT message reports the line speed 

X0 

Basic response codes (codes 0­4,8) 

X1 

Extended response codes (codes 0­5,8,10­12,30­40,60­62) 

X2 

Extended response codes (codes 0­6,8,10­12,30­40,60­62) 

X3 

Extended response codes (codes 0­5,7,8,10­12,30­40,60­62) 

X4 

Extended response codes (codes 0­7,10­12,30­40,60­62) 

X5 

Extended response codes (codes 0­7,10­13,30­40,60­62) 

X6 

Extended response codes (codes 0­5,7­8,10­13,30­40,60­62) 

Zn 

Restore configuration profile n (n=0,1,2,3) 

&B0 

8 bit character length 

&B1 

9 bit character length 

&B2 

10 bit character length 

&B3 

11 bit character length 

&B4 

10 or 11 bit character length determined by autobaud 

&C0 

DCD signal always asserted 

&C1 

DCD signal responds to remote modem 

&C2 

DCD signal always on, pulses low on disconnect 

&C3 

DCD asserted during voice session 

&D0 

Ignore DTR 

&D1 

Return to Local command state if DTR goes low 

&D2 

Hangup & return to Local Com if DTR goes low, disable auto­answer until DTR 

asserted 

&D3 

Initialise with values in &Y profile if DTR goes low 

&F0 

Restore factory defaults

Advertising