System software upgrades

47

The document contains information about SUs for CS 1000.

4

Download the appropriate patches to a location that you can
connect to from the MCG 3100.

5

Log on to the MCG 3100 as nortel.

For more information, see

“Admin shell access” (page 50)

.

6

Transfer the SU you downloaded to the /var/opt/nortel/patch
directory of the MCG 3100.

ATTENTION

The patching software requires all patch files to be stored in the
/var/opt/nortel/patch directory.

7

Access the MCG 3100 command line.

8

To view the current version of software, enter

swVersionShow

The MCG 3100 responds with the current version of the
software, for example:

Configuration installed:

MCG3100

Configuration version:

5.00.20

mobilitybase 2.1-48
nortel-cs1000-linuxbase 5.00.38

9

To install the load, enter

pload

10

When the program prompts

Patch filename?

, enter the patch

filename.

The MCG 3100 installs the SU, and reports on the success of
the installation. For example:

Patch filename?mobilitybase-2.1.75.el4
Patch mobilitybase-2.1.75.el4
Patch successfully installed.

11

To put the SU in service, enter

pins 0

The MCG 3100 responds:

Patch handle:

0

The application mobilitybase should be stopped
before putting in service this Service Update
Do you want to continue?

(Y/N) [N]?

12

Enter

y

The installation continues, displaying its progress. For example:

Performing the installation:
Name :

mobilitybase Relocations:

(not

relocatable)
Version :

2.1 Vendor:

(none)

Release :

75 Build Date:

Thu 14 Feb 2008 12:53:03

PM EST
Install Date:

(not installed) Build Host:

masterserver.sipquest.com
Group Applications/Communications Source RPM:

Nortel Mobile Communication 3100 Series Portfolio

Nortel Mobile Communication Gateway 3100 Installation and Upgrades

NN42030-300

02.03

Standard

9 May 2008