National Instruments VXI/VME 600 User Manual

Page 51

Advertising
background image

Glossary

©

National Instruments Corporation

G-3

VXI/VMEpc 600 Series for Windows 95/NT

C

CLK10

A 10 MHz, ±100 ppm, individually buffered (to each module slot),
differential ECL system clock that is sourced from Slot 0 of a VXIbus
mainframe and distributed to Slots 1 through 12 on P2. It is distributed to
each slot as a single-source, single-destination signal with a matched delay
of under 8 ns.

CMOS

Complementary Metal Oxide Semiconductor; a process used in making
chips

Commander

A message-based device that is also a bus master and can control one or
more Servants

configuration registers

A set of registers through which the system can identify a module device
type, model, manufacturer, address space, and memory requirements. In
order to support automatic system and memory configuration, the VXIbus
specification requires that all VXIbus devices have a set of such registers.

D

Data Transfer Bus

DTB; one of four buses on the VMEbus backplane. The DTB is used by a
bus master to transfer binary data between itself and a slave device.

DMA

Direct Memory Access; a method by which data is transferred between
devices and internal memory without intervention of the central processing
unit

DRAM

Dynamic RAM (Random Access Memory); storage that the computer must
refresh at frequent intervals

driver window

A region of address space that is decoded by the VXI/VMEpc for use by the
NI-VXI software

DTB

See Data Transfer Bus.

E

ECL

Emitter-Coupled Logic

EEPROM

Electronically Erasable Programmable Read Only Memory

Advertising