14

Product description

All Large Systems consist of Universal Equipment Modules (UEM) stacked
one on top of another to form a column. Each column contains a pedestal,
a top cap, and up to four modules. A system can have one column or
multiple columns.

Each UEM is a self-contained unit that houses a card cage and backplane,
power and ground cabling, power units, input/output (I/O) panels, circuit
cards, and cables. When the card cage is installed, the function of the
UEM is established and the module is no longer "universal." The system
modules are as follows:

NT4N41 Core/Network module for CS 1000M MG, CS 1000M SG,
Meridian 1 PBX 81C CP PIV, and Meridian 1 PBX 61C CP PIV

NT5D21 Core/Network module for CS 1000M HG, CS 1000M SG, CS
1000M MG, Option 51C, 61C and 81C

NT8D35 Network module required for CS 1000M MG and Meridian
1 PBX 81C CP PIV, Option 81C

NT8D37 Intelligent Peripheral Equipment (IPE) module (required for
Large Systems)

Fiber Remote IPE module (optional for Large Systems Multi Group)

Carrier Remote IPE module (optional for Large Systems)

The pedestal generally houses a blower unit, air filter, Power Distribution
Unit (PDU), and System Monitor.

The top cap provides airflow exits, I/O cable entry and exit, and overhead
cable-rack mounting. Thermal sensor assemblies for the column are
attached to a perforated panel on top of the highest module in the column,
under the top cap.

A system can have one column or multiple columns. To comply with FCC
and CSA standards for containing electromagnetic interference and radio
frequency interference (EMI/RFI), spacer kits connect the columns in a
multiple-column system. If a Signaling Server is added to a previously
CISPR Class B system (previously used in some specific countries), the
system is now Compliant to Class A.

System options

This document includes information on the following Large Systems:

CS 1000M HG and Meridian 1 Option 51C: enhanced common control
complex, single CPU, and one half network group

CS 1000M SG, Meridian 1 PBX 61C CP PIV, and Meridian 1 Option 61C:
enhanced common control complex, dual CPU, and one full-network
group