Product description

System monitor

Power Distribution Unit (PDU)

Pedestal (one per column)

Blower unit

Thermostat harness

Top cap (one per column)

Air probe harness

System modules

Each type of module is available in AC-powered and DC-powered versions
(except the NT8D36 InterGroup module that does not require power).
AC-power modules generally require a module power distribution unit
(MPDU) to provide circuit breakers for the power supplies. DC-powered
modules do not require an MPDU because a switch on each power supply
performs the same function as the MPDU circuit breakers.

Note: In the UK, DC-powered modules must be used.

The figures in this chapter show a typical configuration for each module. DC
power is represented in these examples.

NT4N41 Core/Network module

This module provides common control and network interface functions. With
the CS 1000M MG and the Meridian 1 PBX 81C CP PIV, two Core/Net
modules are installed side-by-side. With the CS 1000M SG and the Meridian
1 PBX 61C CP PIV, the modules are stacked or mounted side-by-side.

One section of this module houses the common control complex (CPU,
memory, up to four cCNI cards, and mass storage functions). The other
section supports a Conference card, one Peripheral Signaling card, one
3-Port Extender card, and optional network cards.

Note: cCNI card slots 13 and 14 remain empty.

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Large System Overview

NN43021-110

01.03

Standard

Release 5.0

18 February 2008

Copyright © 2003-2008, Nortel Networks

.