Napco Security Technologies GEM-DXRP3 User Manual

Page 17

Advertising
background image

17

K E Y P AD F U N C T I O N S

9.

Reset System Trouble? System troubles display and sound at the keypad.

Correcting the trouble will clear most indications, however the following error codes will
require manual reset: E11; E13; E19; E20 and E22. (See SYSTEM TROUBLE ERROR
CODES for a description of error codes).





10.

Reset Sensor Watch Failure

(Sensor Watch programmed? ‰YES ‰NO).

Your system may have been programmed for Sensor Watch, a feature which supervises
the motion sensors in the system. If a Sensor Watch failure occurs, a System Trouble
E22-NN will result, where NN represents the zone number of the sensor in question. To
reset, press

C

to clear the display, enter the Function Menu, scroll to Reset Sensor

Watch Failure and press

D

.

If you cannot correct the problem, call for service.



11.

Start Exit Time?

(Optional) (Start Exit Time programmed? ‰YES ‰NO)

In Commercial Burglary systems, exit delay may have been programmed to start after a
central-station “ringback” (verification) signal has been received. If the ringback tone
has not been received within about 30 seconds after arming, a communication problem
may exist. Use this function to start exit delay manually, then exit the premises
immediately. Be sure to have your alarm specialist check communications with the
central station as soon as possible.

09

INTERIOR BYPASS FIRE/TBL SYS TBL

CHIME

11

INTERIOR BYPASS FIRE/TBL SYS TBL

CHIME

10

INTERIOR BYPASS FIRE/TBL SYS TBL

CHIME

Advertising