Solid-state relay outputs, Output channels, Solid-state relay outputs -10 – National Instruments 6527 User Manual

Page 26: Output channels -10

Advertising
background image

Chapter 3

Making Signal Connections

6527 User Manual

3-10

ni.com

Solid-State Relay Outputs

On a 6527 device, I/O connector pins 51 through 98, shown in Figure 3-1,
represent the terminals of the solid-state relays.

Output Channels

The output channels of a 6527 device are solid-state relays containing an
LED and two MOSFETs connected together to form a bidirectional switch.
The LH1546 is a solid-state relay. Depending on how the load is connected
to the terminals, an output can either source or sink currents.

Figure 3-5 shows two signal connection examples for driving a load with
these solid-state relays.

Figure 3-5. Signal Connections for Solid-State Relays

Load

R

S

I

f

+5 V

Supply

+

Isolation

Isolated
Ground

Digital
Logic

390

DIG+

6527

DIG–

Load

R

S

I

f

+5 V

Supply

+

Isolation

Isolated
Ground

Digital
Logic

390

DIG+

6527

DIG–

a. Sinking Current

b. Sourcing Current