Appendix A

Specifications

6527 User Manual

A-2

ni.com

Max switching voltage

AC....................................................30 V

RMS

(42 V peak)

DC....................................................60 VDC

Max switching capacity ..........................120 mA

1

Common-mode isolation ........................60 VDC

30 V

RMS

(42 V peak)

(channel-to-channel and
channel-to-computer)

On resistance...........................................35

Ω max; 25 Ω typ

Output capacitance .................................55 pF at 1 V

Off leakage current (max).......................200 nA

Relay set time (max)...............................3.0 ms

Relay reset time (max)............................3.0 ms

Power-on state ........................................Relays open

Overcurrent protection on outputs, typical at 25 °C, V

relay

= 7 V

Current limit ....................................260 mA
Shutdown time.................................1

µs

Overcurrent duration (max) .............1 s

Power Requirement

+5 VDC (±5%) .......................................500 mA max

Power available at I/O connector............+4.5 to +5.25 VDC, fused at 1 A

1

With all relays carrying 120 mA and all inputs driven to 28 V, the total power dissipation can approach 20 W. The maximum

switching capacity in PCI and CompactPCI systems must be derated according to the ambient temperature and cooling
capacity of your system to prevent the device from overheating. (The PXI chassis has built-in fans to handle 25 W per slot.)