Physical, Environment, Safety – National Instruments 6527 User Manual
Page 38

Appendix A
Specifications
© National Instruments Corporation
A-3
Physical
Dimensions (not including connectors)
PCI-6527 ......................................... 17.5
× 10.7 cm (6.9 × 4.2 in.)
PXI-6527......................................... 16
× 10 cm (6.3 × 3.9 in.)
I/O connector.......................................... 100-pin keyed female cable
connector
Environment
Operating temperature............................ 0 to 50
°C
Storage temperature ............................... –20 to 70
°C
Relative humidity ................................... 10% to 90% noncondensing
Functional shock (PXI-6527)................. MIL-T-28800 E Class 3
(per Section 4.5.5.4.1); half-sine
shock pulse, 11 ms duration,
30 g peak, 30 shocks per face
Operational random vibration
(PXI-6527) ............................................. 5 to 500 Hz, 0.31 g
rms
, 3 axes
Nonoperational random vibration
(PXI-6527) ............................................. 5 to 500 Hz, 2.5 g
rms
, 3 axes
Note
Non-operational random vibration profiles were developed in accordance with
MIL-T-28800E and MIL-STD-810E Method 514. Test levels exceed those recommended
in MIL-STD-810E for Category 1 (Basic Transportation, Figures 514.4-1 through
514.4-3).
Safety
Designed in accordance with IEC/EN 61010-1, UL 3111-1, and
CAN/CSA C22.2 No. 1010.1 for electrical measuring and test equipment.
Maximum altitude .................................. 2000 m
Pollution degree ..................................... 2
Overvoltage category ............................. CAT I
Indoor use only