NEVER operate the generator while wearing loose

fitting clothing such as neckties, scarves or untucked
shirts.

NEVER operate the generator, or handle any

electrical equipment while standing in water, while
barefoot, while hands are wet or while in the rain or
snow. Electric shock may result.

NEVER operate the generator under the following

conditions:

A. Excessive change in engine speed, slow or

fast.

B. Overheating in load connecting devices.
C. Sparking or arcs from generator.
D. Loss of electrical output.
E. Damaged receptacles.
F. Engine misfire.
G. Excessive vibration.
H. Enclosed compartments, or confined areas.
I. Flame

or smoke.

J. Rain, snow or wet conditions.
K. Operator non-attendance.
L. Without proper guarding in place.

WARNING

Keep fire extinguisher close

by your generator and be familiar with how to use it.
Consult your local fire department for correct
extinguisher type.

DANGER

Remember, exhaust fumes are

deadly carbon monoxide, a poisonous gas and must
be vented to the outside where there are no people.
Cooling air of sufficient amounts must be brought in
and exhausted out to ensure proper cooling of the
engine and generator.

INSTALLATION

Choose a location where the generator will not be

exposed to rain, snow or direct sunlight. Common
places for mounting your PTO generator are to a trailer
or a cement slab. However you choose to mount the
generator, make sure it can get as close to the load as
possible. This will make using the generator more
convenient and reduce voltage drop.

The installation site must be free from water,

moisture, or dust. Foreign matters, such as dust, dirt,
sand, lint, or abrasive materials can cause damage if
allowed inside the generator. All electrical
components should be protected from excessive
moisture or the insulation system will deteriorate and
result in grounding or shorting out of the generating
sy stem.

Design the application to minimize the angle of the

driveline, 15

° maximum. The smaller the angle of

operation, the longer the driveline will last.

When trailer mounting the generator select a

trailer that is wide enough to withstand the torque of
start-up and loading torque. Wheels that are not
spaced properly could cause the trailer to tip over. The
constant vibration of the generator can cause metal

fatigue of the trailer base if the steel used is not thick
enough.

DANGER

Trailer may tip over and cause

serious injury or death. Never stand near an operating
PTO generator.

Use four, grade 5, 5/8” bolts to mount

generator.

After the generator is firmly mounted , attach the

PTO driveline to the generator then the tractor. Use a
synchronized PTO driveline rated at 48 HP minimum.

DANGER

Never attach PTO driveline

while tractor is running.

DANGER

Always have proper guarding

of rotating parts. Failure to guard the power
transmission mechanisms may result in serious injury
or death.

While seated on the tractor and the engine at idle,

engage the PTO. Slowly increase the throttle until the
needle in the generator voltmeter is at or above the
black line in the green area. A load can now be
applied to the generator. Remember to stay clear of
the rotating PTO driveline. From the tractor seat re-
adjust the speed until the needle on the generator
voltmeter is close to the black line in the green area. If
the needle will not rise to the green area no matter
what the engine speed, the generator is either
overloaded or there is a problem. Use the
troubleshooting guide at the end of the manual for
assistance with possible problems.

Before each use check the gear box oil level. Use

80W-90 SAE synthetic gear oil and fill to the middle of
the oil level sight plug.

LOAD APPLICATION

It is important to determine the total electrical load

before it is connected to the generator. The two major
factors in determining the life of a generator head are:
heat build up, caused by overloading the generator
and corrosive contaminants, that attack the wiring
insulation. If the generator is overloaded, the wires