System troubles – Napco Security Technologies EXPRESS XP-600 User Manual

Page 12

Advertising
background image

The XP600 is constantly monitoring its own components, as well as all critical services, such as AC Power
and the Telephone line, to insure that it is always ready to provide the protection for which it was designed.
When a system trouble does occur, it will caution you by lighting the yellow

ь

ьSYSTEM light and beeping

the keypad buzzer. If you cannot immediately clear the system trouble, the system can still be used.
Simply press

D

to view the trouble as described below, and then arm the system.

In order to determine the nature of the trouble, press

D

, count the number of keypad beeps and observe

the number of the illuminated zone light. Refer to the following table to determine the cause of the trouble.
If there is more than one trouble to be viewed, pressing

D

will scroll to the next, and then exit the

ь

ьSYSTEM mode if there are no additional troubles to view.

ь

ь

System Troubles

Keypad Beeps or

ь

ь

SYSTEM Flashes

Zone light

ON

System Trouble

Condition

Action

1 Beep

1

AC Power Failure

This trouble will occur if AC power is not present. Make sure
system transformer is plugged into AC receptacle and check
circuit breaker, otherwise call installing company for service.

1 Beep

2

Low Battery

If there has been a recent power failure, the battery may be
partially depleted and must be recharged by the control
panel. If the trouble does not go away in 24 hours, call in-
stalling company for service.

1 Beep

3

Communication
Failure

The system was not able to report to central station. If this is
due to a temporary interruption in the telephone service, the
trouble can be cleared when the service is restored by press-
ing

D

. Otherwise, call installing company for service.

1 Beep

4

Telephone Line Cut

The telephone line has failed. If telephone service has been
temporarily interrupted, the trouble will clear it is when re-
stored. Otherwise, call installing company for service.

2 Beeps

1

Bell/Siren Trouble

There is a problem with the Bell or Siren. Call installing com-
pany for service.

FIRE

AC

SYSTEM

READY

ZONE 3

ZONE 1

ZONE 2

ZONE 5

ZONE 6

ZONE 4

ARMED

12

Oi218a.pub
page 12

Thursday, December 18, 1997 18:29

Advertising