Specifications

VXI-USB User Manual

A-2

ni.com

Shock and Vibration

Operational shock ...................................30 g peak, half-sine, 11 ms pulse

(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)

Random vibration

Operating .........................................5 to 500 Hz, 0.3 g

rms

Nonoperating ...................................5 to 500 Hz, 2.4 g

rms

(Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.)

Power Requirement

+5 V (excluding downstream USB devices)

Typical.............................................2 A

Maximum ........................................4 A

–5.2 V

Typical.............................................200 mA

Maximum ........................................500 mA

–2 V

Typical.............................................100 mA

Maximum ........................................250 mA

Physical

Size .........................................................C size, C-1

Dimensions ............................................. 23.3

× 43.0 cm (9.2 × 13.4 in.)

Weight ....................................................1.14 kg (2.5 lb)

I/O connectors

USB device (Series A).....................2

USB host (Series B).........................1

SMB.................................................3