Table 4. tb-2709 cabling options, Specifications, Input/output – National Instruments PXI Terminal Block NI TB-2709 User Manual

Page 8

Advertising
background image

NI TB-2709 Installation Guide

8

ni.com

Table 4 lists the National Instruments cables available for connecting the
TB-2709 to both analog and digital user signals.

Specifications

This section lists the specifications of the TB-2709. These specifications
are typical at 25 °C unless otherwise specified.

Input/Output

Refer to the documentation for your PXI-6123/6133 or PXI-6122/6132
S Series device to determine the input/output specifications for your
application.

Caution

Do not apply an input voltage greater than 42 V

pk

/60 VDC to the TB-2709. Input

voltages greater than 42 V

pk

/60 VDC can damage the TB-2709 and any device connected

to it, including the host computer. Overvoltage can also cause an electric shock hazard for
the operator. National Instruments is not liable for damage or injury resulting from such
misuse.

9

White/Black

P0.5

10

White/Brown

P0.6

11

White/Red

P0.7

12

Drain Wire

CHASSIS GND

13

White/Orange

CTR 1 OUT

14

White/Yellow

PFI 9

Table 4. TB-2709 Cabling Options

Cable

Length

Part Number

SMB-100, SMB Female to BNC
Female Coaxial, 50

Ω

0.6 m

763389-01

SMB110, SMB to BNC Male
Coaxial, 50

Ω

1 m

763405-01

14-Pos MFIT-Pigtail Cable
Assembly

1 m

194123-01

Table 3. TB-2709 Wiring Information for 14-Pos MFIT-Pigtail

Cable Assembly (Part Number 194123-01) (Continued)

Pin Number