Physical, Shock and vibration, Environment – National Instruments PXI Terminal Block NI TB-2709 User Manual

Page 9

Advertising
background image

© National Instruments Corporation

9

NI TB-2709 Installation Guide

Physical

Dimensions

Height.............................................. 10.7

Ч 8.6 Ч 2.0 cm

(4.2

Ч 3.4 Ч 0.8 in.)

Weight............................................. 144.6 g (5.1 oz)

I/O connectors

68-position SCSI-II type ................. 1, female

SMB jacks....................................... 9

14-pin auxiliary connector .............. One, Molex 14-pin microfit

connector

Shock and Vibration

Operational shock .................................. 30 g peak, half-sine, 11 ms pulse

(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)

Random vibration

Operating ........................................ 5 to 500 Hz, 0.3 g

rms

Nonoperating .................................. 5 to 500 Hz, 2.4 g

rms

(Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.)

Environment

The NI TB-2709 is intended for indoor use only.

Operating temperature............................ 0 to 55 °C

Storage temperature ............................... –20 to 70 °C

Relative humidity ................................... 10 to 90% noncondensing

Pollution Degree .................................... 2