Routing a signal to counter n aux, Counter n a, counter n b, and counter n z signals, Routing signals to a, b, and z counter inputs – National Instruments NI 6232 User Manual

Page 102: Routing counter n z signal to an output terminal, Counter n up_down signal, Routing a signal to counter n aux -29, Counter n up_down signal -29

Advertising
background image

Chapter 7

Counters

© National Instruments Corporation

7-29

NI 6232/6233 User Manual

Routing a Signal to Counter n Aux

Each counter has independent input selectors for the Counter n Aux signal.
Any of the following signals can be routed to the Counter n Aux input.

RTSI <0..7>

Input PFI <0..5>

ai/ReferenceTrigger

ai/StartTrigger

PXI_STAR

In addition, Counter 1 Internal Output, Counter 1 Gate, Counter 1 Source,
or Counter 0 Gate can be routed to Counter 0 Aux. Counter 0 Internal
Output, Counter 0 Gate, Counter 0 Source, or Counter 1 Gate can be routed
to Counter 1 Aux.

Some of these options may not be available in some driver software.

Counter n A, Counter n B, and Counter n Z Signals

Counter n B can control the direction of counting in edge counting
applications.

Use the A, B, and Z inputs to each counter when measuring quadrature
encoders or measuring two pulse encoders.

Routing Signals to A, B, and Z Counter Inputs

Each counter has independent input selectors for each of the A, B, and Z
inputs. Any of the following signals can be routed to each input.

RTSI <0..7>

Input PFI <0..5>

PXI_STAR

Routing Counter n Z Signal to an Output Terminal

You can route Counter n Z out to RTSI <0..7>.

Counter n Up_Down Signal

Counter n Up_Down is another name for the Counter n B signal.

Advertising
This manual is related to the following products: