NI 9237 Operating Instructions and Specifications
Overvoltage protection
between any two pins........................ ±30 V
Accuracy
Gain drift........................................... 10 ppm/°C max
Offset drift
2.5 V excitation .......................... 0.6
μV/V per °C
3.3 V excitation .......................... 0.5
μV/V per °C
5 V excitation ............................. 0.3
μV/V per °C
10 V excitation ........................... 0.2
μV/V per °C
Measurement Conditions
*
Percent of
Reading
(Gain Error)
Percent of
Range
**
(Offset Error)
Calibrated typ (25 °C, ±5 °C)
0.05%
0.05%
Calibrated max (–40 to 70 °C)
0.20%
0.25%
Uncalibrated typ (25 °C, ±5 °C)
0.20%
0.1%
Uncalibrated max (– 40 to 70 °C)
0.60%
0.35%
*
Before offset null or shunt calibration.
**
Range equals 25 mV/V.