Mode 1 input timing – National Instruments PC-DIO-96 User Manual

Page 33

Advertising
background image

Chapter 2

Configuration and Installation

© National Instruments Corporation

2-15

PC-DIO-96 User Manual

Mode 1 Input Timing

The following figure illustrates the timing specifications for an input transfer in mode 1.

T3

T5

T6

T7

T4

T1

T2

STB*

IBF

INTR

RD*

DATA

Name

Description

Minimum

Maximum

T1

STB* pulse width

100

T2

STB* = 0 to IBF = 1

150

T3

Data before STB* = 1

20

T4

STB* = 1 to INTR = 1

150

T5

Data after STB* = 1

50

T6

RD* = 0 to INTR = 0

200

T7

RD* = 1 to IBF = 0

150

All timing values are in nanoseconds.

Advertising