Table 4-3. Mode 0 I/O Configurations

Control Word

Group A

Group B

Number

Bit

Port A

Port C

1

Port B

Port C

2

76543210

0

10000000

Output

Output

Output

Output

1

10000001

Output

Output

Output

Input

2

10000010

Output

Output

Input

Output

3

10000011

Output

Output

Input

Input

4

10001000

Output

Input

Output

Output

5

10001001

Output

Input

Output

Input

6

10001010

Output

Input

Input

Output

7

10001011

Output

Input

Input

Input

8

10010000

Input

Output

Output

Output

9

10010001

Input

Output

Output

Input

10

10010010

Input

Output

Input

Output

11

10010011

Input

Output

Input

Input

12

10011000

Input

Input

Output

Output

13

10011001

Input

Input

Output

Input

14

10011010

Input

Input

Input

Output

15

10011011

Input

Input

Input

Input

1

Upper nibble of port C

2

Lower nibble of port C

Mode 0 Programming Example

The following example shows how to configure PPI A for various combinations of mode 0 input
and output. This code is strictly an example and is not intended to be used without modification
in a practical situation.

Main() {

#define BASE_ADDRESS

0x180

/* Board located at address 180 */

#define APORTAoffset

0x00

/* Offset for PPI A, port A */

#define APORTBoffset

0x01

/* Offset for PPI A, port B */

#define APORTCoffset

0x02

/* Offset for PPI A, port C */

#define ACNFGoffset

0x03

/* Offset for PPI A, CNFG */

unsigned int porta, portb, portc, cnfg;
char valread;

/* Variable to store data read from a

port */

/* Calculate register addresses */