Register description for the 8253, Figure 4-2, Control-word format for the 8253 – National Instruments PC-DIO-96 User Manual

Page 42: Table 4-2, Port c set/reset control words

Advertising
background image

Register-Level Programming

Chapter 4

PC-DIO-96 User Manual

4-4

© National Instruments Corporation

Warning:

During programming, note that each time a port is configured, output ports A
and C are reset to 0, and output port B is undefined.

Table 4-2 shows the control words for setting or resetting each bit in port C. Notice that bit 7 of
the control word is cleared when programming the set/reset option for the bits of port C.

Table 4-2. Port C Set/Reset Control Words

Bit

Bit Set

Bit Reset

The Bit Set or

Number

Control Word

Control Word

Reset in Port C

0

0xxx0001

0xxx0000

xxxxxxxb

1

0xxx0011

0xxx0010

xxxxxxbx

2

0xxx0101

0xxx0100

xxxxxbxx

3

0xxx0111

0xxx0110

xxxxbxxx

4

0xxx1001

0xxx1000

xxxbxxxx

5

0xxx1011

0xxx1010

xxbxxxxx

6

0xxx1101

0xxx1100

xbxxxxxx

7

0xxx1111

0xxx1110

bxxxxxxx

Register Description for the 8253

Figure 4-2 shows the control word format used to completely program the 8253. Bits 7 and 6 of
the control word select the counter to be programmed. Bits 5 and 4 select the mode by which the
count data is written to and read from the selected counter. Bits 3, 2, and 1 select the mode for
the selected counter. Bit 0 selects whether the counter counts in binary or BCD format.

BCD

D2

D1

D0

D3

D7

D6

D5

D4

1 = count in BCD
0 = count in binary

Mode Select
000 = mode 0
001 = mode 1
010 = mode 2
011 = mode 3
100 = mode 4
101 = mode 5
110 = mode 2
111 = mode 3

Access Mode

00 = latch counter value
01 = access LSB only
10 = access MSB only
11 = access LSB, then MSB

Counter Select
00 = counter 0
01 = counter 1
10 = counter 2
11 = illegal

Figure 4-2. Control-Word Format for the 8253