Triggers analog trigger – National Instruments NI 6115/6120 User Manual

Page 95

Advertising
background image

Appendix A

Specifications

NI 6115/6120 User Manual

A-16

ni.com

Base clock accuracy................................±0.01%

Max source frequency.............................20 MHz

Min source pulse duration .....................10 ns, edge-detect mode

Min gate pulse duration .........................10 ns, edge-detect mode

Data transfers ..........................................DMA, interrupts,

programmed I/O

DMA modes ...........................................Scatter-gather

Triggers

Analog Trigger

NI 6115/6120 source ..............................All analog input channels,

external trigger (PFI0/TRIG1)

Level .......................................................± full-scale, internal;

±10 V, external

Slope .......................................................Positive or negative

(software selectable)

Resolution

NI 6115............................................8 bits, 1 in 256

NI 6120............................................12 bits, 1 in 4,096

Hysteresis................................................Programmable

Bandwidth ..............................................(–3 dB) 5 MHz internal/external

External input (PFI0/TRIG1)

Impedance........................................10 k

Coupling ..........................................AC/DC

Protection.........................................–0.5 V to (V

CC

+ 0.5) V when

configured as a digital signal,
±35 V when configured as an
analog trigger signal or disabled,
±35 V powered off

Advertising