SNTP General

SNTP Client: Enables/Disables the SNTP Client to contact the configured server on UDP port 123 and set the local time
Default: disable

Server Name: Sets the NTP server name or IP address to which the SNTP Client has to contact to update the time
Default: 127.0.0.1

Time Zone: Sets the time zone
Default: UTC

Time Zone offset: Sets the offset time from UTC
Default: +00:00 (+/-hh:mm)

Polling Time: Sets the polling time at which SNTP client requests the server to update the time
Default: 300 minutes

Daylight Saving: Enables/Disables the Day Light Saving Mode
Default: enable

Daylight Saving offset: Sets the offset to use during the Day Light Saving Mode
Default: +60 (+/-mm)

SNTP Daylight Saving Configuration

Start Ordinal: Sets the start ordinal to use during the Day Light Saving Mode. Options - first/second/third/forth/last
Default: first

End Ordinal: Sets the last ordinal to use during the Day Light Saving Mode. Options - first/second/third/forth/last
Default: last

Start Month: Sets the start month to use during the Day Light Saving Mode
Default: april

End Month: Sets the end month to use during the Day Light Saving Mode
Default: october

Start Day: Sets the start weekday to use during the Day Light Saving Mode
Default: sunday

End Day: Sets the end weekday to use during the Day Light Saving Mode
Default: sunday

Start Time: Sets the start time to use during the Day Light Saving Mode
Default: 02:00 (hh:mm)

End Time: Sets the end time to use during the Day Light Saving Mode.
Default: 02:00 (hh:mm)

Commands

User can enter any "set" commands as per the manual

View Statistics

Bridge: Displays the Bridge Statistics only when bridge is enabled

eth0: Displays Ethernet Statistics

serial: Displays Serial Statistics

PPP: Displays PPP Statistics only when PPP is enabled

Users: Displays the Default and Added users of the module

System Information: Displays the System information of the module. Processor details, Uptime, Memory utilization, Flash Memory map, Version, Date,
Binary details

Save

Upon clicking Save button, it prompts for confirmation

If selected OK, the modified configuration is written into flash and if the box may reboot for few configuration changes. After few seconds, the
default.html/http-s0.html page will be launched again as per configuration. If the page is not launched, check the IP address and HTTP configuration status

If selected CANCEL, the browser is redirected to General Configuration page

Restore Defaults

Upon clicking Restore Defaults button, it prompts for confirmation

If selected OK, the configuration is restored to factory defaults and redirected to General Configuration page. User need to click save button to save the