Power requirement, Physical, Figure 4. scc-ao10 dimensions – National Instruments Isolated Analog Output Module SCC-AO10 User Manual

Page 8

Advertising
background image

SCC-AO10 Isolated Analog Output Module User Guide

8

ni.com

Power Requirement

Analog power .........................................180 mW max at full load

172 mW max with no load

+15 V...............................................6 mA max at full load

5.73 mA max with no load

–15 V ...............................................6 mA max at full load

5.73 mA max with no load

Digital power (

+5 V) ..............................1.15 W max at full load

600 mW max with no load

+5 V.................................................230 mA max

120 mA max with no load

Physical

Figure 4. SCC-AO10 Dimensions

Weight ....................................................28 g (1.0 oz)

I/O connectors.........................................One 20-pin right-angle male

connector; one 3-pin screw
terminal

Field-wiring diameter .............................28 to 16 AWG

1.87 cm

(0.74 in.)

7.93 cm

(3.12 in.)

3.55 cm

(1.4 in.)

Advertising