The following specifications are typical for a range of
–40 to +70 °C, unless otherwise noted.

Encoder Input

Number of channels .......................... 4

Input type

Single-ended............................... V

IL

= 0.0–0.8 V

V

IH

= 2.0–250.0 V

Differential ................................. ±0.3 V provided one input

falls between 0.0 and 3.0 V
and the other input falls
between 0.0 and 250 V

Maximum protected input voltage.... ±250 VDC on each input

Input bandwidth ................................ 250 kHz for each input

Encoder frequency ............................ 1 million counts/second

Minimum input pulse width.............. 2

µ

s

Isolation ............................................ 2,500 Vrms

Safety isolation, working voltage ..... 250 Vrms, designed per

IEC 1010 as double insulated

External supply voltage (V).............. 8 to 30 VDC, user-provided

at 5 W

I/O supply voltage (Vsup) ................ 5 VDC at 600 mA maximum

Physical

Indicators .......................................... Green POWER and READY

indicators

Weight............................................... 143 g (5.1 oz.)

Power Requirements

Power from network module ............ 1.2 W maximum

Environment

Operating temperature ...................... –40 to +70 °C

Storage temperature .......................... –55 to +85 °C

Relative humidity.............................. 5% to 90%, non-condensing