Power supply, Ac input, Dc outputs – NCR 7458 User Manual

Page 72

Advertising
background image

3-48 Chapter 3: Hardware Service

Power Supply

The power supply provides power to the 7458 Terminal, as well as
various retail peripherals through the powered connectors. The power
supply is controlled by a logic on/off switch, which permits it to be
disabled through software. An AC outlet without a switch is provided
at the rear of the power supply for AC power to a CRT
Other features include:
• Internal UPS including a battery charger and harness to 24 V lead

acid batteries

• Un-switched AC convenience outlet (for CRT)
• Auto sensing for 115 VAC/230 VAC operation
• Cooling fan
• TTL voltage compatible UPS signal harness (~UPS_OFF,

AC_GOOD, ~BATT_SENSE, and BATT_LO signals)

• AUX peripheral power harness
Functionally, the terminal’s ON/OFF switch controls the power supply
control logic (~REM_EN) to activate the power supply. This switch
does not control actual AC mains voltage applied to the power supply.

AC Input

The power supply operates with the following voltage ranges.

Range Nominal

Vrms

Minimum

Vrms

Maximum

Vrms

Input Current Max. Arms

Including

CRT

Convenience Outlet

LOW (115) 100-127

90

136

5.3 A

8.3 A

HIGH (230) 200-240

180

265

2.6 A

4.6 A

DC Outputs

The power supply has the following DC outputs:

Voltage

+3.3 V

+5 V

+12 V

-12 V

+5 VSB

+24 V

Max. Current

10.0 A * 12.0 A * 11.5 A

0.25 A

2.0 A

2.3 A