Operation (cont’d) – North Star M165938N User Manual

Page 28

Advertising
background image

Operation (cont’d)

28

•

Always dissipate static charge from your body before beginning
the fueling process by touching a grounded metal object at a safe
distance from fuel sources.

•

Never fill the generator’s gas tank directly from the fuel pump –
the generator’s tank is not grounded and high velocity flow from
the pump can cause static electricity build-up. Use an approved
portable container to transfer gas to the generator’s tank.

•

Never fill the portable gas container while it is sitting inside a
vehicle, trailer, trunk, or pick-up truck bed. ALWAYS place
container on the ground to be filled.

•

Keep nozzle in contact with portable container while filling.
Manually control the flow of gasoline; do NOT use nozzle’s lock-
open device.

•

A portable container made of metal or conductive plastic is
preferred because it dissipates charge to ground more readily.


5) Clean up gasoline spills /splashes immediately.

• If possible, move the generator

away from spilled gasoline on the

ground.

• Wipe up spilled gasoline, and wait 5 minutes for excess gasoline to

evaporate before starting engine.

• Gasoline soaked rags are flammable and should be disposed of

properly.

•

If gasoline is spilled on your skin or clothes, change clothes and
wash skin immediately.

6) Replace gasoline cap securely before starting engine.

7) Store extra gasoline in a cool, dry place in an UL-approved, tightly sealed

container.

IMPORTANT:
For continuous operation, be prepared to check and refuel the engine on
a regular basis.

A tank of gasoline should last about 4 hours under

100% load, and about 8 hours under 50% load.

Start LPG/NG
supply
(if using)

Propane (LPG):
1) Make sure the fuel hose is securely connected to the propane tank

regulator on one end, and the ¾” NPT gas inlet on the generator base on
the other end.

2) Open the propane tank main valve.
3) Check ¾” NPT gas inlet connection for leaks each time you connect. Use

the leak test method described below.

Natural Gas:
1) Make sure the gas line is securely connected to the ¾” inlet on the

generator base.

2) Open line valve, if gas line is so equipped.
3) Check ¾” NPT gas inlet connection for leaks each time you connect.

Use the leak test method described below.

Advertising