Inspect fuel system /
check for leaks

Inspect the fuel system and check for leaks on a regular basis.

1) Inspect the entire fuel system. Look for: signs of leaks or deterioration,

chafed or spongy fuel hose, loose connections, loose or missing fuel hose
clamps, damaged gasoline tank, or defective gasoline shut-off valve.

2) If you are using LPG or NG, test for leaks. After opening LPG/NG

supply valve, apply a soap and water solution over pipes, hoses, and
connections. Soap bubbles will form if there is a leak. Use this method
to test after each reconnection to NG/LPG supply (such as after
transporting generator), and on a regular basis thereafter.

Check GFCI
(if equipped)

Once a month, test the Ground Fault Circuit Interrupter (GFCI) to
protect against electrical shock due to failure of the GFCI.
(Only for
those models equipped with GFCI – See the “Specifications” section.)

To test the GFCI:
1. Depress the TEST button. The RESET button should extend from the

receptacle. If the RESET button does not extend, contact NorthStar for
replacement parts.

2. Restore power to the GFCI by firmly pressing the RESET button back

into the receptacle until an audible click is heard.

Clean & inspect
spark arrestor
(if equipped)

Clean and inspect the spark arrestor muffler. (Only for those models
equipped with a spark arrestor – See the “Specifications” section.)

If the engine is equipped with a spark arrester muffler, clean and inspect it
regularly (follow manufacturer’s service instructions). Replace if damaged.

Keep generator
clean

Keep generator clean.
If dust or debris accumulates on the generator, clean the generator with a
damp cloth or soft bristle brush. Do not allow air intakes to become blocked.

Note: Do not spray generator with a garden hose or pressure washer.
Water may enter the generator and cause damage to the rotor, stator, or
internal windings.

Recharge and
maintain battery
(if electric start)

Inspect, recharge, and maintain your battery according to your battery
manufacturer’s instructions.
(Only for those models equipped with electric
start.)

Do not store with battery charger always connected. Batteries that are over-
charged can boil themselves dry and produce excessive amounts of hydrogen,
an explosive gas.


IMPORTANT:
If a part needs replacement, only use parts that meet the manufacturer’s specifications. Replace-
ment parts that do not meet specifications may result in a safety hazard or poor operation of the
generator.

Contact NorthStar Product Support at 1-800-270-0810