5.7.5 ADDING VENT SECTIONS

Add chimney sections, according to the manufacturers installation instructions. For ease of assembly, a 7”
telescoping pipe may be installed over the 4” vent connection of the adapter. Add vent sections, twist locking
(clockwise) securely, to the required height. The chimney must extend at least, 3 feet above its point of contact
with the roof and at least 2 feet higher than any wall, roof or building within 10 feet horizontally.

59.1

3 FT

MIN

3 FT

MIN

3 FT

MIN

3 FT

MIN

10 FT OR

MORE

LESS THAN

10 FT

FLAT ROOF

WALL

2 FT

MIN

10 FT TO

NEAREST

ROOFLINE

RIDGE

LESS THAN

10 FEET

2 FT MIN

2 FT

MIN

FIGURE 5.7.5a