W415-0788 / A / 09.22.09

Main burner and
pilot cycles on
and off.
GS600 ONLY

Venting is spilling.

-

Test with spill switch bypassed. Replace if defective.

-

Check for vent blockage.

GDS600 ONLY

GDS600 ONLY

42.7_3

SYMPTOM

PROBLEM

TEST SOLUTION

White / grey fi lm
forms.

Sulphur from fuel is being
deposited on glass, logs or
combustion chamber
surfaces.

-

Clean the glass with a recommended gas appliance
glass cleaner. DO NOT CLEAN GLASS WHEN
HOT.

-

If deposits are not cleaned off regularly, the glass
may become permanently marked.

Flames are very
aggressive.

Door is ajar.

-

Tighten door clamps.

Venting action is too great.

-

Restrict vent exit with restrictor plate. See
“RESTRICTING VENTS” section.

Main burner fl ame
is a blue, lazy,
transparent
fl ame.

Blockage in vent.

-

Remove blockage. In really cold conditions, ice
buildup may occur on the terminal and should be
removed.

Compromised venting.

-

Check venting system parameters (seal, length,
rise, etc.).

GLASS EMBERS ONLY:
Too many glass embers.

-

Re-distribute glass embers so that only a single
layer is over top of the burner tube.

Main burner goes
out: pilot goes out.

Vent recirculation.

-

Check joint seals and installation.