0 optional blower installation – Napoleon Fireplaces GDS60N User Manual

Page 38

Advertising
background image

38

W415-0788 / A / 09.22.09

7.0 OPTIONAL BLOWER INSTALLATION

7.0.1 Ensure that the access cover plate has been

installed. For location, see "SWITCH AND
BRACKET INSTALLATION" section.

7.0.2 Remove the on/off switch bracket and the cover

plate below it. The switch spacers and cover
plate may now be discarded.

7.0.3 Decide which side of the blower housing you

prefer the on/off switch to be located on.

7.0.4 Remove the top 2 screws from the left outer

edge of the rear appliance panel.

7.0.5 Mount and secure the blower housing using 4

screws (two of which were removed in previous
step). Ensure that the on/off switch wires pass
through the appropriate slot located on either
side of the blower housing.

7.0.6 Remove the 2 screws from the side of the

blower housing that you want the switch to be located on
and re-secure the on/off switch.

Because the blower is thermally activated, when turned
on, it will automatically start approximately 15-30 minutes
after lighting the appliance and will run for approximately
30-45 minutes after the appliance has been turned off.
Use of the fan increases the output of heat.

Drywall dust will penetrate into blower bearings causing
irreparable damage and must be prevented from coming
into contact with the blower or its compartment.

Any damage resulting from this condition is not covered
by the warranty policy.

SLOT

REMOVED SCREWS

FIGURE 7.0.4 / 7.0.6

FIGURE 7.0.6

FIGURE 7.0.5

Advertising
This manual is related to the following products: