Specifications

BNC-2140 User Manual

A-2

ni.com

Voltage compliance ................................24 V

Excitation overvoltage protection...........±42.4 V (30 V

rms

) powered on

or off

Analog Output

Number of channels................................2 (See the Caution in the

Analog

Output Signal Connections

section in Chapter 3,

Signal Connections

.)

Output coupling ......................................DC

Power Requirement (from DSA device)

Power consumption ................................400 mA at +5 VDC

Physical

Dimensions .............................................14.4 by 11.2 by 5.5 cm

(5.7 by 4.4 by 2.2 in.)

I/O connectors

I/O signals........................................6 BNC connectors (outer shell

isolated from box metal)

DSA device connection ...................68-pin 0.8 mm VHDCI female

connector

Environment

Operating temperature ............................0 to 40 °C

Storage temperature ................................–55 to 150 °C

Relative humidity ...................................5 to 90% non-condensing