Installation, Rigid pipe venting systems, Horizontal or vertical terminations – Regency P131 User Manual

Page 15

Advertising
background image

Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace

15

Pipe Length

Vertical

Terminal

Storm Collar

Part # 953

Flashing

943 or 943S

Ceiling Firestop

(Part # 963)

24" Pipe

Length

Adj.Pipe Length

11" - 14-5/8"

90 Elbow

o

Horizontal

Termination

Cap

Wall Thimble

(Part # 942)

(Required in

Canada)

Vinyl Siding

Standoff (Optional)

(Part #950)

Rigid Pipe Adaptor

(Part #510-994)

45 Elbow

o

RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations

The minimum components required for a basic horizontal termination
are:

1 Simpson

Duravent

Adaptor

1 Horizontal

Termination

Cap

1 45

o

Elbow

1 Rigid

Pipe

Adaptor

1 Wall

Thimble

1 Length of pipe to suit wall thickness
(see

chart)

Wall thickness is measured from the back standoffs to the inside mounting
surface of termination cap. For siding other than vinyl furring strips may
be used, instead of the vinyl siding standoff, to create a level surface to
mount the vent terminal. The Terminal must not be recessed into siding.
Measure the wall thickness including furring strips.

If a Vinyl Siding Standoff is required (it must be used with vinyl siding),
measure to outside surface of wall without siding and add 2 inches.

INSTALLATION

Flat Wall Installation

Wall Thickness Vent Length

(inches) Required (inches)

4"

-

5-1/2"

6"

7"

-

8-1/2"

9"

10"

-

11-1/2"

12"

9"

-

14-1/2" 11" - 14-5/8" Adj. Pipe

15"

-

23-1/2"

17" - 24" Adj. Pipe

This product has been evaluated by Intertek for
using a Dura-Vent Flue Adaptor in conjunction
with Selkirk Direct-Temp and Ameri Vent Direct
venting systems. Use of these systems with the
Direct Vent GS starting collar is deemed accept-
able and does not affect the Intertek WHI listing
of components.

WARNING:

Do not combine venting components from
different venting systems.

However use of the the AstroCap

TM

and FPI

Riser is acceptable with all systems.

When using piping other than Simpson

Dura-Vent, 3 screws must be used to

secure rigid pipe to adaptor.

The FPI AstroCap

TM

and FPI Riser Vent terminal is certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent®, Direct Vent GS,

American Metal Products, Ameri Vent Direct vent and Selkirk Direct-Temp. FPI

TM

, and FPI AstroCap

TM

are the proprietary trademarks of FPI Fireplace

Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

Advertising