INSTALLATION

CHECKLIST

1) Locate

appliance

a) Room location, page 8.

b) C l e a r a n c e s t o C o m b u s t i b l e s ,

page 9.

c)

Mantle

Clearances,

page

9.

d) Framing & Finishing Requirements,

page

10.

e)

Venting

Requirements,

pages

11-20.

2) Assemble Top Standoffs, page (NOTE:

page 11 must be done before installing
unit into fi replace.)

3) Install vent, pages 20-22.

4) Make gas connections. Test the pilot. Must

be as per diagram. Page 23.

5) Install log set where indicated on

page 25-26.

6) Glass Door Removal (page 27), Louvers or

Grills (page 27), and Finishing Trim (page
27).

7) Install optional Wall Switch, Remote Con-

trol, or Wall Thermostat, page 28.

8) Final

check.

Before leaving this unit with the customer,
the installer must ensure that the appliance is
fi ring correctly and operation fully explained
to customer.

This includes:

1) Clocking the appliance to ensure the correct

fi ring rate (rate noted on label 40,000 Btu/h
NG, and 39,000 Btu/h LP) after burning
appliance for 15 minutes.

2) If required, adjusting the primary air to

ensure that the fl ame does not carbon.
First allow the unit to burn for 15-20 min.
to stabilize.

CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.

INSTALLATION

IMPORTANT:

SAVE THESE

INSTRUCTIONS

The Panorama P121/P121LC/P121RC/P131-
NG1 or P121/P121LC/P121RC/P131-LP1 Direct
Vent Fireplace must be installed in accordance
with these instructions. Carefully read all the
instructions in this manual fi rst. Consult the
"authority having jurisdiction" to determine the
need for a permit prior to starting the installation.
It is the responsibility of the installer to ensure
this fi replace is installed in compliance with
manufacturer's instructions and all applicable
codes.

BEFORE YOU START

Safe installation and operation of this appli-
ance requires common sense, however, we
are required by the Canadian Safety Standards
and ANSI Standards to make you aware of the
following:

2) See general construction and assembly

instructions. The appliance and vent should
be enclosed.

3) This appliance must be connected to the

specifi ed vent and termination cap to the
outside of the building envelope. Never vent
to another room or inside a building. Make
sure that the vent is fi tted as per Venting
instructions.

4) Inspect the venting system annually for

blockage and any signs of deterioration.

5) Venting terminals shall not be recessed into

a wall or siding.

6) Any safety glass removed for servicing

must be replaced prior to operating the
appliance.

7) To prevent injury, do not allow anyone who

is unfamiliar with the operation to use the
fi replace.

8) Wear gloves and safety glasses for protec-

tion while doing required maintenance.

9) Be aware of electrical wiring locations in

walls and ceilings when cutting holes for
termination.

10) Under no circumstances should this ap-

pliance be modifi ed. Parts that have to be
removed for servicing should be replaced
prior to operating this appliance.

11) Installation and any repairs to this appliance

should be done by a qualifi ed service per-
son. A professional service person should
be called to inspect this appliance annually.
Make it a practice to have all of your gas
appliances checked annually.

12) Do not slam shut or strike the glass door.

13) Under no circumstances should any solid

fuels (wood, paper, cardboard, coal, etc.)
be used in this appliance.

14) The appliance area must be kept clear and

free of combustible materials, (gases and
other fl ammable vapours and liquids).

INSTALLATION AND REPAIR SHOULD
BE DONE BY A QUALIFIED SERVICE
PERSON. THE APPLIANCE SHOULD
BE INSPECTED BEFORE USE AND
AT LEAST ANNUALLY BY A PRO-
FESSIONAL SERVICE PERSON.
MORE FREQUENT CLEANING MAY
BE REQUIRED DUE TO EXCESSIVE
LINT FROM CARPETING, BEDDING
MATERIAL, ETC. IT IS IMPERATIVE
THAT CONTROL COMPARTMENTS,
BURNERS AND CIRCULATING AIR
PASSAGEWAYS OF THE APPLIANCE
BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED
OUT OF TRAFFIC AND AWAY FROM
FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID
YOUR WARRANTY AND MAY CAUSE
A SERIOUS HOUSE FIRE.

CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.

CHILDREN AND ADULTS SHOULD
BE ALERTED TO THE HAZARDS OF
HIGH SURFACE TEMPERATURES, ES-
PECIALLY THE FIREPLACE GLASS,
AND SHOULD STAY AWAY TO AVOID
BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE

CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.

GENERAL SAFETY

INFORMATION

1) The appliance installation must conform

with local codes or, in the absence of
local codes, with the current Canadian
or National Gas Codes, CAN1-B149 or
ANSI Z223.1 Installation Codes.

Emissions from burning wood or gas could
contain chemicals known to the State of Cali-
fornia to cause cancer, birth defects or other
reproductive harm.

Note: These units are