Maintenance, Log replacement, Thermopile/ thermocouple – Regency P131 User Manual

Page 32: Glass gasket, Door glass, Gold-plated accessories, Maintenance instructions

Advertising
background image

Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace

32

MAINTENANCE

2) Remove the Cap, and shine a fl ashlight

down the Vent. Remove any bird nests, or
other foreign material.

3) Check for evidences of excessive condensa-

tion, such as water droplets forming in the
inner liner, and subsequently dripping out the
joints, Continuous condensation can cause
corrosion of caps, pipe, and fi ttings. It may
be caused by having excessive lateral runs,
too many elbows, and exterior portions of the
system being exposed to cold weather.

4) Inspect joints, to verify that no pipe sections

or fi ttings have been disturbed, and conse-
quently loosened. Also check mechanical
supports such as Wall Straps, or plumbers'
tape for rigidity.

LOG REPLACEMENT

The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door and carefully remove the
logs. (The pilot light generates enough heat to
burn someone.) If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagrams under Log
Installation.

Note: Improper positioning of logs may cre-

ate carbon build-up and will severely
alter the unit's performance which is
not covered under warranty.

THERMOPILE/

THERMOCOUPLE

1) Open the Bottom Louvers or Grills. Remove

the Top Louver or Grill.

2) Remove the Trim Kit, Glass Door, Log Set,

Grate and Burner Assembly (see page
26).

3) Disconnect thermocouple by loosening nut

from the valve with a 9mm wrench. Discon-
nect thermopile by loosening 2 screws
marked TP on the valve.

4) Remove 2 screws from the pilot assembly

and pull up far enough to be able to loosen
the thermocouple or thermopile with a 7/16"
wrench. NOTE: the pilot line is very fragile,
use caution when pulling it up.

5) Drop the thermocouple or thermopile down

through the extrusion and pull it out of the
unit.

6) Reinstall the new ones in reverse order.

GLASS GASKET


If the glass gasket requires replacement use a
tadpole glass gasket (Part # 936-155).

DOOR GLASS

Your Regency fi replace is supplied with high
temperature 5mm-Tempered glass & 5mm-Ce-
ramic glass. If your glass requires cleaning, we
recommend using an approved glass cleaner
available at all authorized dealers. Do not use
abrasive materials.

CAUTION & WARNINGS:

* Do not clean when the glass is hot.
* The use of substitute glass will void all prod-
uct

warranties.

* Care must be taken to avoid breakage of
the

glass.

* Do not strike or abuse the glass.
* Do not operate this fi replace without the
glass

front or with a cracked or broken

glass front.
* Wear gloves when removing damaged or
broken glass.
* Replacement of the glass panels should be
done by a licensed or qualifi ed service per
son.

GLASS REPLACEMENT

In the event that you break your glass by
impact, purchase your replacement from an
authorized Regency dealer only. Replacement
glass is shipped already installed into the door
frame. Reinstall as per Glass Door Installation
on page 23.

REPLACEMENT PARTS:

Front Door - Tempered (Part# 360-528)
Side Door - Tempered (Part# 360-529)
Front Door - Ceramic (Part# 360-538)
Side Door - Ceramic (Part# 360-539)

GOLD-PLATED

ACCESSORIES

The 24 carat gold-plated fi nish requires little
maintenance, and need only be cleaned with a
damp cloth. DO NOT use abrasive materials or
chemical cleaners, as they may harm the fi nish
and void the warranty. Clean any fi ngerprints
off before turning the unit on.

MAINTENANCE

INSTRUCTIONS

1) Always turn off the gas valve before cleaning.

For relighting, refer to lighting instructions.
Keep the burner and control compartment
clean by brushing and vacuuming at least
once a year. When cleaning the logs, use a
soft clean paint brush as the logs are fragile
and easily damaged.

2) Clean appliance and door with a damp

cloth (never when unit is hot). Never use
an abrasive cleaner. The glass should be
cleaned with a gas fi replace glass cleaner.
The glass should be cleaned when it
starts looking cloudy.

3) The heater is fi nished in a heat resistant

paint and should only be refi nished with heat
resistant paint. Regency uses StoveBright
Paint - Metallic Black #6309.

4) Make a periodic check of burner for proper

position and condition. Visually check the
fl ame of the burner periodically, making sure
the fl ames are steady; not lifting or fl oating.
If there is a problem, call a qualifi ed service
person.

5) The appliance and venting system must be

inspected before use, and at least annually,
by a qualifi ed fi eld service person, to ensure
that the fl ow of combustion and ventilation
air is not obstructed.

Note: Never operate the appliance with-

out the glass properly secured in
place.

6) Do not use this appliance if any part has been

under water. Immediately call a qualifi ed
service technician to inspect the appliance
and to replace nay part of the control system
and any gas control which has been under
water.

7) In the event this appliance has been serviced

check that the vent-air system has been
properly resealed & reinstalled in accord-
ance with the manufacturer's instructions.

8) Verify operation after servicing.

General Vent Maintenance

Conduct an inspection of the venting system
semi-annually. Recommended areas to inspect
as follows:

1) Check the Venting System for corrosion in

areas that are exposed to the elements.
These will appear as rust spots or streaks,
and in extreme cases, holes. These com-
ponents should be replaced immediately.

Advertising