1) When selecting a location for your stove,

ensure that the clearances are met as out-
lined on page 9.

2) Provide adequate clearances for servic-

ing.

3) The appliance must be installed on a fl at,

solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed on
carpeting, combustible linoleum tile or other
combustible material other than wood fl oor-
ing, the appliance must be installed on a
metal or wood panel extending the full width
and depth of the appliance.

4) The Direct Vent Gas Fireplace can be in-

stalled as follows:

Model #

Position

A) P121-1:

See

Thru

B) P131-1:

Pier

C) P121LC-1:

Left

Corner

D) P121RC-1:

Right

Corner

5) This appliance is Listed for bedroom instal-

lations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.

6) The P121-1/P121LC-1/P121RC-1/P131-1

Direct Vent Gas Fireplace is approved for
alcove installations, which meet the clear-
ances listed on this page.

7) We recommend that you plan your instal-

lation on paper using exact measurements
for clearances and fl oor protection before
actually installing this appliance. Have a
qualifi ed inspector, dealer, or installer review
your plans before installation.

Note: For Exterior Vent Termination

Locations see page 12.

.