Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace

28

Option 1:

REMOTE CONTROL

Can be used with Option 2 or 3

but not both.

Use the Regency Remote Control Kit approved
for this unit. Use of other systems may void
your warranty.

The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.

1) Choose a convenient location on the wall

to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fi replace
to that location. Use the Thermostat Wire
Table.

2) Connect the two wires to the gas valve. See

diagram below.

Option 2:

WALL SWITCH

Can be used with Option 1 or 3

but not both.

1) Run the supplied 15' of wire through the back

gas inlet opening. Be careful not to damage
wire.

Note: We recommend a maximum of 15'

of wire but if you wish to go with a
longer run, use the Thermostat Wire
Table.

2) Connect the wire to the supplied wall switch

and install into the receptacle box.

Thermostat Wire Table

Option 3:

WALL THERMOSTAT

Can be used with Option 1 or 2

but not both.

A wall thermostat may be installed if desired,
connect the wires as per the wiring diagram.
Use the table below to determine the maximum
wire length.

Note: Preferable if the thermostat is installed
on an interior wall.

Regency offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.

3) Install 3 AAA alkaline batteries in transmitter

and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.

INSTALLATION

CAUTION

Do not connect millivolt re-

mote control wires to a 120V

wire.

CAUTION

Do not connect millivolt

wall switch wire to a 120V wire.

CAUTION

Do not connect millivolt

wall thermostat wires

to a 120V wire.

14 GA.
16 GA.
18 GA.
20 GA.
22 GA.

50 Ft.
32 Ft.
20 Ft.
12 Ft.

9 Ft.

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size Max. Length

Advertising