Chapter 5. trigger settings [trigger, Selecting the pad type [f1 (bank), For access to trigger parameters (p. 44) – Roland TD-12 User Manual

Page 44

Advertising
background image

44

Chapter 5. Trigger Settings [TRIGGER]

To be sure the TD-12 accurately receives signals sent from the
pads, select the

trigger type

(the type of pads being used) for

each trigger input.

Trigger Type

A

trigger type

is a group of trigger settings with values

optimally adjusted for a particular pad. Indications such as
“KD85,” “PD85,” or “VH11,” etc. in the above display
correspond to this. When you select a trigger type for a
connected pad, each of the parameters is set to the most
appropriate values for that pad, allowing you to play it
without encountering problems with the settings. Only when
factors unrelated to the selection of the proper trigger type
prevent you from getting good results in performance should
you fine-tune the individual parameters for the pad you are
using.

Trigger Bank

Trigger Banks

allow you to store the 15 trigger settings as a

single unit of information. The large number at the left edge of
the above display is the Trigger Bank number. Move the
cursor to this area to select the Trigger Bank.

1.

Press [TRIGGER] - [F1 (BANK)].

[TRIGGER] lights, and the “TRIGGER BANK” screen
appears.

fig.05-TrigBank_70

2.

Press [CURSOR (left)] to move the cursor to the

Trigger Bank number.

3.

Use [+/-] or [VALUE] to select the Trigger Bank.

4.

Press [CURSOR (right)] to move the cursor to a

trigger type.

5.

Strike the pad you wish to set.

The cursor moves to the trigger type for the struck pad.

You can also select by using [CURSOR] or [TRIG
SELECT].

6.

Use [+/-] or [VALUE] to select the trigger type.

* When you select the trigger type, the trigger parameters (except

the crosstalk cancel parameters) are automatically set to the
most efficient values for each pad. Make settings for the
parameter as needed.

* When 3Way Trigger (p. 52) is set to ON, “RD CTRL” is

displayed for the trigger type for TRIGGER INPUT 10 EDGE.
It cannot be changed.

* Brush sweep and Cross Stick can be used only on SNARE.

* Each playing method can be used with the instruments

corresponding to it (p. 91).

Selecting the Pad Type
[F1 (BANK)]

Trigger Type

Used Model

PD125

PD-125

PD120

PD-120

PD105

PD-105

PD100

PD-100

PD80R

PD-85, PD-80R, PD-80

PD9

PD-9

PD8

PD-8

PD7

PD-7

PD6

PD-6

KD120

KD-120

KD80

KD-85, KD-80

KD8

KD-8

KD7

KD-7

CY15R

CY-15R

CY12RC

CY-12R/C

CY14C

CY-14C

CY8

CY-8

CY6

CY-6

CY12H

CY-12H

VH12

VH-12

VH11

VH-11

PAD1

When using a non-Roland pad

PAD2
RT7K

RT-7K

RT5S

RT-5S

RT3T

RT-3T

Trigger Inputs and Pad/Playing
Methods corresponding chart

Trigger In-
put

Dual Trigger
Mesh Pad

Positional
Sensing

Rim Shot
Nuance

KICK

SNARE

o

o

o

TOM 1–3

o

o

HI-HAT

CRASH 1, 2

RIDE

o

EDGE

AUX 1, 2

o

o

TD-12_e.book 44 ページ 2005年2月18日 金曜日 午後6時39分

Advertising
This manual is related to the following products: