Regency

®

L234 Direct Vent Gas Insert

11

INST

ALLA

TION

CONVERTING FROM 3" & 3" VENTING TO 3" & 2"

1) Remove the top plate from the unit by undoing the screw at the front

of the fi rebox and slide out towards the back of the unit.

VENT RESTRICTOR POSITION

The Vent Restrictor plate is located on the inside top of the fi rebox.

To change the vent restrictor position, refer to the instructions below;

1) Remove the glass door.

2) Remove brick panels if installed.

3) Remove the 4 screws that hold the vent restrictor plate in place.

2) Remove the 3" collar from the top plate by undoing the 4 screws.

NOTE: The screws are secured from the underside of the top plate.

Underside of Top Plate

3) Secure the 2" collar to the top plate using 4 screws in place of the 3"

collar.

4) Re-install the top plate to the unit.

Top Plate with 2" Collar shown on Unit

4) Adjust the vent restrictor plate to the required vent restrictor
position.

5) Once the vent restrictor plate is in the required position, secure using

the 4 screws removed from step 3.

6) Re-install brick panels if removed.

7) Re-install glass door.

INSTALLATION

Factory Set at 1"

1"

Adjusted to 3/4"

3/4"

Advertising
This manual is related to the following products: