Maintenance – Regency L234-NG User Manual

Page 33

Advertising
background image

Regency

®

L234 Direct Vent Gas Insert

33

MAINTENANCE

MAINTENANCE

11) Unplug the fan connector wires.

12) Remove the 2 screws that hold the fan bracket

in place.

13) Remove the fan by sliding the fan forward

and lift up and out.

14) Remove the ground screw which holds the

ground wire.

Ground Wire

15) Replace the fan.

NOTE: Bend the connector clips down before
re-installing the fan cover plate.

Connector Clips

16) Reverse steps 14 - 1.

10) Remove the fan cover plate by undoing the

12 screws that hold it in place.

Fan Cover Plate Removed

Advertising
This manual is related to the following products: