Installation, Inst alla tion, Fig.4 – Regency L234-NG User Manual

Page 15

Advertising
background image

Regency

®

L234 Direct Vent Gas Insert

15

INST

ALLA

TION

INSTALLATION

9) Remove burner orifi ce with a 1/2" wrench

and discard.

10) Install the new LP burner orifi ce stamped

#54 and tighten.

11) Pull off the pilot cap to expose the pilot
orifi

ce.

12) Unscrew the pilot orifi ce with the supplied

allen key and replace it with the LP pilot orifi ce
in the kit and re-install the pilot cap.

13) From the valve remove the black protec-

tion cap by hand from the high-low knob
(Fig.1).

Fig. 1

14) Insert the allen key

into the hexagonal
key-way of the screw
(Fig. 2), rotate it
counter-clockwise
until it is free and
extract it.

Fig.2

15) Check that the screw is clean and if

necessary remove dirt.

16) Flip the screw (Fig. 3).

17) Using the allen key as shown in Fig.4,

rotate the screw clockwise until snug, do
not overtighten.

Fig.3

Fig.4

WARNING!

Do not overtighten the screw.

Recommended to

grip the wrench by the short side.

18) Verify that if the conversion is from NG to

LPG, the screw must be re-assembled
with the red o-ring visible (Fig. 5).

LPG Configuration

Red o-ring visible

Fig.5

20) Attach the label "This unit has been con-

verted to Propane" near or on top of the
serial # decal.

21) Replace yellow "Natural Gas" label with red

"LPG" label.

22) Reverse steps 8) to 1).

NOTE: Before re-installing the burner,
check the LP areation settings.

23) Check the inlet and outlet pressures.

24) Check operation of fl ame control.

25) Check for proper fl ame appearance.

19) Re-assemble the black protection cap

(Fig. 6).

WARNING!

Also check that the pilot and main

burner injectors

are appropriate for the gas type.

Fig. 6

Advertising
This manual is related to the following products: