Installation, Gas insert aeration system, Gas connection – Regency L234-NG User Manual

Page 12: Flue liner installation, Inst alla tion

Advertising
background image

Regency

®

L234 Direct Vent Gas Insert

12

INST

ALLA

TION

GAS INSERT

AERATION SYSTEM

The burner aeration is factory set but may need adjusting due to either
the local gas supply or altitude. Open the air shutter for a blue fl ame
or close for a more yellow fl ame.

GAS CONNECTION

GAS CONNECTION WARNING:

Only persons licensed to work with gas piping may

make the necessary gas connections to this appliance.

1) When the appliance is to be installed into either an existing masonry

chimney system or factory built fi replace, thoroughly clean the
chimney before installation.

2) A 3/8" NPT gas supply pipe must be brought near the inlet hole.

The valve inlet is on the right side of the unit.

3) Locate the center point where the vent will pass through the chimney

above the appliance. Move the appliance into the exact location
where it is to be installed. Ensure that the Insert is level.

NOTE: This unit is equipped with a heat sensor thermodisc which
will prevent the blower from operating until the unit reaches the
correct temperature.

5) Install

ashing.

6) Insert both liners into chimney, passing through the damper open-

ing.

7) Install

termination

cap.

8) Connect

the

marked end of the liner to the exhaust collar of the

vent connector plate marked with an "E", seal connection with high
temperature silicone. Secure with gear clamp or screws.

NOTE:
1)
Final gas connection should be made after unit is in place to avoid

damage to the liner when pushing the unit into position.

2) Mill-pac may be used instead of high tempture silicone and screws

may be used instead of gear clamps at connections of liner to inlet
and vent collars.

9) Connect the 2nd liner to the intake collar, seal connection with high

temperature silicone. Secure with gear clamp or screws.

10) Align vent connector plate with guides on unit.

11) Slide unit into masonry opening, while ensuring that the slots at the

rear of the connector plate mates up with the hold down plate on
the unit.

12) Secure with screw.

FLUE LINER

INSTALLATION

1) Cut the fl ex liner as required.

2) Mark the end of one liner with an "E" to indicate Exhaust.

3) Connect the other end of the above liner to the exhaust side of the

termination cap, seal connection with high temperature silicone.
Secure with gear clamp or screws.

4) Connect the 2nd liner to the inlet side of the cap, seal connection

with high temperature silicone. Secure with gear clamp or screws.

INSTALLATION

Minimum Air Shutter Openings

Vent Run

Burner Aeration

Setting

3" x 3"

8' to 20'

NG: 3/16"

LP: 3/16"

20' to 35'

NG: 3/16"

LP: 3/16"

3" x 2"

8' to 20'

NG: 3/16"

LP: 3/16"

20' to 35'

NG: 1/8"

LP: 1/8"

CAUTION: Carbon will be produced if the air shutter is closed

too much.

Note: Any damage due to carboning resulting from improperly setting

the aeration controls is NOT covered under warranty.

Note: Aeration Adjustment should only be performed by an authorized

FPI Installer at the time of installation or service.