background image

Chapter 8: Nodes, Node Groups, and Interfaces

145

Column
number

Tag or value

Details

10

Description

Optional.

To add an IPMI power control interface to the CSV file:

Column
number

Tag or value

Details

1

ADD

The first column for all tags is the
command ADD.

2

NODE-IPMI-INTERFACE

Enter the tag as shown.

Tags are not case sensitive.

3

Node Name

Required field.

4

Interface Name

Required field.

5

IP Address or Hostname

Required field.

6

UDP Port

Default is 623

7

Authentication

MD5, None, OEM, or PASSWORD

Default is PASSWORD.

8

Interval

Enter the check interval in seconds.
Default is 550.

9

Service Account Name

Leave blank if specifying username
and password.

10

Username

Leave blank if specifying service
account.

11

Password

Leave blank if specifying service
account.

12

Description

Optional.

To add a managed powerstrip interface to the CSV file:

Column
number

Tag or value

Details

1

ADD

The first column for all tags is the
command ADD.

2

NODE-POWER-INTERFACE Enter the tag as shown.

Tags are not case sensitive.

3

Node Name

Required field.

4

Interface Name

Required field.

Advertising