Operations commands, Pre l iminar y – Runco LIGHTSTYLE LS-3 User Manual

Page 90

Advertising
background image

Serial Communications

74

Runco LS-3/LS-5 Installation/Operation Manual

PRE

L

IMINAR

Y

Operations Commands

Operations commands allow more flexible and direct control of the projector. The syntax
for operations commands is as follows:

op <operation> <command>[CR]

(Precede

<operation> and <command> with a space.)

The command type can be one of 5 functions:

asp.16.9

(none)

0x9E

0xDE

Apply 16:9 aspect ratio to the active
source.

asp.4.3

(none)

0x9F

0xDF

Apply 4:3 aspect ratio to the active source.

asp.lett

(none)

0xA0

0xE0

Apply Letterbox aspect ratio to the active
source.

asp.narr

(none)

0xA1

0xE1

Apply 4:3 Narrow aspect ratio to the active
source.

pip.sw

0xA3

0xE3

Switch to next “PIP Select” state.

pip.1

(none)

0xA4

0xE4

Change “PIP Select” to source 1.

pip.2

(none)

0xA5

0xE5

Change “PIP Select” to source 2.

pip.3

(none)

0xA6

0xE6

Change “PIP Select” to source 3.

pip.4

(none)

0xA7

0xE7

Change “PIP Select” to source 4.

pip.5

(none)

0xA8

0xE8

Change “PIP Select” to source 5.

pip.off

(none)

0xA9

0xE9

Change “PIP Select” to off.

pip.swap

0xAA

0xEA

Swap the PIP image with the active source
image.

pow.tog

(none)

0xAC

0xEC

Toggles between power on and power off.

lit.tog

0xAD

0xED

Activates remote backlighting only when
pressed momentarily. When held for five
seconds or more, the IR code for toggling
the projector I/O panel light is transmitted.

Table 6-1. Serial Command Key Names and IR Codes (continued)

RS232

Keyname

Remote Button

IR Code

Description

Set 1

Set 2

PIP

SWAP

LIGHT

Operations Control Commands

Function

Command

Action on unit

Set

= <value>

Makes the unit take that value.

Get

?

Asks what the current value is.

Increment

+

Adds 1 to the current value.