6earth leakage breaker – Ricoh LD335c User Manual

Page 164

Advertising
background image

Remarks

152

6

Earth Leakage Breaker

To prevent electric shock this ma-
chine has an earth leakage breaker.
The earth leakage breaker is normally
in the on position.
Once a month, check that it functions
properly by following the procedure
below.

Important

❒ If the earth leakage breaker is not

functioning normally, contact your
sales or service representative.

AAAA

Make sure the exposure glass cov-
er or the ADF is closed.

BBBB

Turn off the power.

Reference

⇒ p.29 “Turning Off the Pow-
er”, p.29 “Turning Off the Main
Power”

CCCC

If the finisher is installed, detach
it from the machine.

Note

❒ The above illustration shows

the 2 tray finisher. If you are us-
ing the Booklet finisher, detach
it in the same way.

DDDD

Using the tip of a ball-point pen,
press the test button of the earth
leakage breaker.

EEEE

Confirm that the earth leakage
breaker switch moves to the off
position.

FFFF

Turn the switch to the on posi-
tion.

ADL015S

ADL010S

ADL012S

ADL013S

JupiterC2_GSG_EN_Pre_FM.book Page 152 Tuesday, December 28, 2004 1:39 PM