background image

Section 2, Mounting the Oasis™ Heating Module

• Combustion air must be drawn from an outside source and

cannot contain any combustible gases.

• Oasis™ Heating Module must be mounted in an area that

provides unrestricted access to the front panel. Allow space for
connection to the fuel and coolant lines, as well as the power
and exhaust connections. (Minimum of 10” top clearance - top
exhaust version; minimum of 6” top clearance - bottom
exhaust version; 0” clearance to all other Oasis™ Heating

Module surfaces). Allow 1” clearance on the sides for attaching
the mounting brackets.

• Mount the unit with the front panel side facing out and

accessible. Facing out simplifies installation and maintenance.

• Oasis™ Heating Module must be mounted horizontal and level

using eight, 1/4” through bolts and 1” diameter fender

washers, lock washers and nuts.

Figure 2-1: Module Dimensions

Oasis™ Heating Module must not be installed or operated in any

compartment with flammable gases.

! DANGER

If the Oasis™ Heating Module is going to be mounted in the engine
compartment, check for adequate ventilation. When the engine is

running this area could be under a negative pressure. Make sure
the air-intake and exhaust hoses have no leaks and are well
fastened to the heater, muffler and thru-hull fitting. Assembly

! WARNING